{"product_id":"v-e-m-mes-100-60-current-transformer-1000-5a-class-0-5-10va","title":"V.E.M. MES-100\/60 Current Transformer – 1000\/5A, Class 0.5, 10VA","description":"\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eIndustrial Precision for 1000A Main Distribution.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"6\"\u003eThe \u003cb data-path-to-node=\"6\" data-index-in-node=\"4\"\u003eV.E.M. MES-100\/60\u003c\/b\u003e is a heavy-duty \u003cb data-path-to-node=\"6\" data-index-in-node=\"38\"\u003eSolid Core Current Transformer (CT)\u003c\/b\u003e designed for critical metering on high-current 1000 Amp systems.\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eFeaturing a generous \u003cb data-path-to-node=\"7\" data-index-in-node=\"21\"\u003e60mm window aperture\u003c\/b\u003e, this transformer is built to accommodate large busbars and heavy-gauge cables found in main switchboards and industrial incomers. Its solid-core design ensures maximum magnetic efficiency and stability, making it the standard choice for permanent, high-reliability installations.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eWith a substantial \u003cb data-path-to-node=\"8\" data-index-in-node=\"19\"\u003e10VA rated burden\u003c\/b\u003e, this unit is capable of driving signals over long cable runs to distant metering panels without loss of quality. Combined with \u003cb data-path-to-node=\"8\" data-index-in-node=\"165\"\u003eClass 0.5 accuracy\u003c\/b\u003e, it ensures revenue-grade precision for billing and detailed energy analysis.\u003c\/p\u003e\n\u003cp data-path-to-node=\"9\"\u003e\u003cb data-path-to-node=\"9\" data-index-in-node=\"0\"\u003eKey Features:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-path-to-node=\"10,0,0\"\u003e\n\u003cb data-path-to-node=\"10,0,0\" data-index-in-node=\"0\"\u003e1000A High Capacity:\u003c\/b\u003e Ideally sized for main distribution panels and heavy industrial loads.\u003c\/li\u003e\n\u003cli data-path-to-node=\"10,1,0\"\u003e\n\u003cb data-path-to-node=\"10,1,0\" data-index-in-node=\"0\"\u003eLarge 60mm Window:\u003c\/b\u003e Easily fits around the large conductors and busbars required for 1000A currents.\u003c\/li\u003e\n\u003cli data-path-to-node=\"10,2,0\"\u003e\n\u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"0\"\u003eLong-Range Signal:\u003c\/b\u003e A \u003cb data-path-to-node=\"10,2,0\" data-index-in-node=\"21\"\u003e10 VA\u003c\/b\u003e burden allows for accurate metering even when instruments are located far from the source.\u003c\/li\u003e\n\u003cli data-path-to-node=\"10,3,0\"\u003e\n\u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"0\"\u003eRevenue-Grade Accuracy:\u003c\/b\u003e Rated \u003cb data-path-to-node=\"10,3,0\" data-index-in-node=\"30\"\u003eClass 0.5\u003c\/b\u003e for precise energy management and cost allocation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-path-to-node=\"11\"\u003e\u003cb data-path-to-node=\"11\" data-index-in-node=\"0\"\u003eTechnical Specifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003ctable data-path-to-node=\"12\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,0,0\"\u003e\u003cb data-path-to-node=\"12,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,1,1,0\"\u003eMES-100\/60\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,0,0\"\u003e\u003cb data-path-to-node=\"12,2,0,0\" data-index-in-node=\"0\"\u003ePrimary Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,2,1,0\"\u003e1000 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,0,0\"\u003e\u003cb data-path-to-node=\"12,3,0,0\" data-index-in-node=\"0\"\u003eSecondary Current\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,3,1,0\"\u003e5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,0,0\"\u003e\u003cb data-path-to-node=\"12,4,0,0\" data-index-in-node=\"0\"\u003eAccuracy Class\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,4,1,0\"\u003e0.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,0,0\"\u003e\u003cb data-path-to-node=\"12,5,0,0\" data-index-in-node=\"0\"\u003eRated Burden\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,5,1,0\"\u003e10 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,0,0\"\u003e\u003cb data-path-to-node=\"12,6,0,0\" data-index-in-node=\"0\"\u003eWindow Size\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,6,1,0\"\u003e60 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,0,0\"\u003e\u003cb data-path-to-node=\"12,7,0,0\" data-index-in-node=\"0\"\u003eCore Type\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,7,1,0\"\u003eSolid Core (Window Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,0,0\"\u003e\u003cb data-path-to-node=\"12,8,0,0\" data-index-in-node=\"0\"\u003eFrequency\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"12,8,1,0\"\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0790\/4952\/3518\/files\/VEM-MES-Current-Transformer-Datasheet.pdf?v=1791196872\" target=\"_blank\" rel=\"noopener\"\u003eDownload Datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"V.E.M.","offers":[{"title":"Default Title","offer_id":53046539223358,"sku":"DIX-MES-100\/60-1000\/5A","price":11.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0790\/4952\/3518\/files\/HTB1cfcEJwHqK1RjSZFkq6x.WFXaZ.webp?v=1791215599","url":"https:\/\/azargroup.org\/products\/v-e-m-mes-100-60-current-transformer-1000-5a-class-0-5-10va","provider":"Azar Group","version":"1.0","type":"link"}